Ignition Flag

“Ignition flag” section contains:

Select the parameter, based on which Omnicomm Online software will record the event of VH ignition as on/off.

Possible values depending on the type of terminal being connected:

• “Always switched-on”. This Method of calculation is a default value or is set up if ignition on/off control is not required. Omnicomm Online software will display a permanently on ignition. Therefore, the parameters based on ignition on/off data will not be calculated;

• “Ignition flag”. This Method of calculation is set up if a third-party terminal transmits ignition on/off data depending on the position of the ignition key.

• “Main power”. This Method of calculation is set up if a third-party terminal transmits data about the availability of the main power and backup battery power. Omnicomm Online software will record ignition on if the terminal is energised from the backup battery;

• “Engine speed”. This Method of calculation is set up if a third-party terminal transmits the engine speed values. Omnicomm Online software will record ignition on when engine speed values are above 0;

• ”Movement flag.” This Method of calculation is set up if a third-party terminal transmits the event “moving”. Omnicomm Online software will record ignition on if the terminal transmits the event “moving”;

• “Discrete input”. This Method of calculation is set up if a discrete third-party terminal input is connected to the signal from the ignition key. Omnicomm Online software will record ignition on when it receives the event of discrete input on from the third-party terminal.

If it is required to record ignition on when receiving the event of discrete input off, tick the box “Invert”.

Flag “Engine speed CAN”. This Method of calculation is set up if the third-party terminal transmits engine speed values from the bus CAN. Omnicomm Online software will record ignition on when receiving from the third-party terminal the events with engine speed data from the bus CAN.

• “Analogue input”. This Method of calculation is set up if an analogue input of the third-party terminal is connected to the ignition key signal. Omnicomm Online software will record ignition on whe the analogue input voltage exceeds “Threshold value, В”.

If it is required to record ignition on when the analogue input voltage is less than “Threshold value”, tick the box “Invert”.

• “Main power”. This Method of calculation is set up if the third-party terminal transmits data about main power availability. Omnicomm Online software will record ignition on when the VH onboard power network voltage exceeds “Threshold value”.

If it is required to record ignition on when the VH onboard power network voltage is less than “Threshold value”, tick the box “Invert”.