Calibration

Omnicomm ICON display supports up to 4 fuel tanks. The maximum number of Omnicomm LLS fuel level sensors is 4.

Add fuel tanks

To add calibration tables for fuel level sensors, in the “Used tanks” section press the “Add tank” button.

A window will open, where you select a .ctb file with calibration tables for Omnicomm LLS fuel level sensors. The calibration tables must contain no more than 64 lines. The maximum fuel volume in the tank is 65534 liters.

To view and edit the calibration tables, press the “Calibration tables” button.

The calibration tables

Parameters Display on the Screen

Omnicomm ICON display supports up to 30 main screens with different sets of parameters (only when connected to a terminal). For each main screen you can select up to 5 parameters. To display the parameters, configure the display according to the Omnicomm terminals user manual.

Parameters setting on the screen

List of parameters:

  • Temperature of 1-wire 1..8 – temperature from the sensors connected to the terminal. Values for 8 temperature sensors may be displayed
  • UI1..6 – reading from the terminal universal input. Values for 6 universal inputs may be displayed
  • Speed – vehicle speed according to the terminal readings
  • Number of the tank
  • Total fuel volume in the tanks
  • USS – fuel volume dispensed through the dispensing gun of the fuel-servicing truck when using the PPO-USS device (only for Omnicomm Profi)
  • Engine hours – value of engine hours

Press “Add parameter”.

Add parameter

For each parameter, specify:

  • Units of measurement – units of measurement for the parameter. Select the units of measurement from the list or add your own by selecting “Other”. Enter the unit of measurement in the “Unit name” field
  • Measurement accuracy – select the number of digits after decimal point to display. Possible values: 1, 2, 3
  • Minimum threshold – enter the minimum value of the measured parameter
  • Maximum threshold – enter the maximum value of the measured parameter
  • Sound notification – enable/disable sound notification if thresholds of monitored parameters are exceeded
  • SMS sending – enable/disable SMS sending if thresholds of monitored parameters are exceeded

Arrange the parameters by holding down the left mouse button and moving the parameter to the desired location:

Arrange the parameters

To add a main screen press “Add screen”.

If you change the connection type to the "Fuel level sensor", the configured main screens will be deleted.

Driver’s Status

The Omnicomm ICON display supports up to 10 driver’s statuses.

In the “States” section:

Driver’s Status

Press “Add status”.

Enter the status in words and press the “Record into device“ button.

The “Refueling” status is always present in the Omnicomm ICON display and used to monitor the refueling volume.

Brightness

To adjust brightness when the main screen is displayed, press and hold the corresponding button:

Brightness

The program finishes the brightness adjustment and switches to the main screen automatically in a few seconds, or you can do it by left-clicking the mouse.

Notification Volume

To adjust volume when the main screen is displayed, press and hold the corresponding button:

Notification Volume

The program finishes the volume adjustment and switches to the main screen automatically in a few seconds, or you can do it by left-clicking the mouse.