Omnicomm PORT Module

1. Power up Omnicomm PORT

2. Start your laptop and turn on Wi-Fi

3. Connect to the Wi-Fi network. Default network name – “Mobile-CS”, default password – “Mob1Com2Ser3”

4. In the browser, enter the Omnicomm PORT setting interface address. Default value – 192.168.5.100:8088. A window will open:

Authorization window

Default values:

  • “Login” – enter “admin”
  • “Pass” – enter “lcsadm”

Click “Enter”. A window with Omnicomm PORT settings will open:

Configuration window

Data Transfer via Wi-Fi to the Communication Server

Configure the settings of the available Wi-Fi access point that will be used to transmit data to the communication server.

In the section “Access point for Omnicomm PORT”:

  • Open the 2.4 GHz or 5 GHz tab, depending on the frequency of the Wi-Fi access point
  • “Network selection” - select “Manual input” or find the network name in the list
  • “Network name” - enter the name of the Wi-Fi access point if manual input was chosen. If you have selected a network name from the list, this field will be filled in automatically
  • “Password” - enter the password for the access point
  • “Encryption” - “WPA2-Personal”
  • “DHCP” - enable to automatically assign an IP address to the device. In this case, the assigned IP address will be displayed in the “Static IP” field

If you need to manually assign a static IP address to the device, uncheck the DHCP box. In the “Static IP” field, enter the IP address that you wish to assign to the device. Enter the subnet mask and addresses of DNS1 and DNS2 servers.

Settings of the Wi-Fi access point

There is no data transfer via satellite Internet channels.

Data Transfer via Mobile Networks

Mobile settings

  • “Access point name (APN)” - select “Manual input” or choose from the list
  • “Host” - enter the name of the GPRS access point if manual input was chosen. If you have selected an access point name from the list, this field will be filled in automatically
  • “APN Login” and “APN Password” – enter the login and password for the APN access point. Some mobile network providers supply a login and a password together with the SIM card

When using second-generation (2G) mobile networks, stable Omnicomm PORT operation is not guaranteed due to the insufficient data transfer rate.

In order to transfer data, collected by PORT in 1 day by from 30 terminals to the CS within no more than 1 hour, the Internet channel must meet the following requirements:

  • Available uplink bandwidth - at least 64 kbit/s
  • Available downlink bandwidth - at least 16 kbit/s
  • Ping value from PORT to online.omnicomm.ru - up to 600 ms

Data Receipt via Wi-Fi from the Omnicomm Profi Wi-Fi Terminals

Configure the settings of the Omnicomm PORT Wi-Fi access point, which will be used to receive data from Omnicomm Profi Wi-Fi terminals.

If the IP address is changed, the address of the Omnicomm PORT setup interface will change to the set address.

Wi-Fi

  • “Network name (SSID)” - enter the name of the Omnicomm PORT Wi-Fi access point. Default value – Mobile-CS
  • “Password” - enter the password to connect to the Omnicomm PORT Wi-Fi access point. Default value – Mob1Com2Ser3
  • “Encryption” - select “WPA2-Personal”
  • “Channel” - select the least busy channel
  • “Static IP” - set the IP address of the Omnicomm PORT. Default value: 192.168.5.100
  • “Port” - set the port value for Omnicomm PORT. Default value – 9977

There is no data transfer via satellite Internet channels.

Connection to the Communication Server

Connection to the communication server

  • “CS 1 IP address or domain name” – enter IP address or domain name of the communication server. Default value – cs.omnicomm.ru
  • “Port” – specify the port to be used by the terminal to connect to the communication server. Default value – 5445

Access to Omnicomm PORT Settings

Setting up access

“Login” and “Password” - enter the login and password to be used for authorization in the Omnicomm PORT configuration interface.

Access to the Settings of Data Transfer to the LCS

Setting up access

“Login” and “Password” - enter the login and password to be used for authorization in the local communication server.

Setting Storage Time

Setting storage time

“Setting storage time, h” - enter the period of time after which the terminal settings will be deleted from Omnicomm PORT. Possible values: from 12h to 1440h Default value – 1440.

List of Terminals

To configure the settings in the Omnicomm Profi Wi-Fi 3.0 terminal when you connect to Omnicomm PORT for the first time, add the terminal ID, vehicle name, and password to the table. Password - the terminal's password for access to the remote configuration server.

List of terminals

This table also establishes the correspondence between the terminal ID and the vehicle name to display in the local communication server.

Selecting the Loading Mode

Omnicomm PORT supports two modes of data loading depending on the available Internet connection speed.

Selecting the loading mode

Check the “Use with slow connection” box if your Internet connection to the CS does not provide a response time (ping) of less than 150 ms, a download speed greater than 100 Kbps and a packet loss of less than 20%.

Automatic Data Transmission to the Communication Server

In the browser, enter the address of the local communication server. Default value – 192.168.5.100:8090. A window will open:

Authorization window

“Login” – enter “user”

“Pass” – enter “pass”

Click “Log in”. A window will open:

Main window

Click the “Information and settings” button and go to the “Data transfer to the CS” section:

Settings and information

Check the “Transfer to the CS on timer” box.

Ensure that the values in the fields “CS1 IP address or domain name” and “Port” correspond to those indicated in the section Connecting to the communication server

Firmware Update

Updating the firmware to version 1.3.1 will reset the previous settings and clear the data archive. Export the data first if you wish to save the archive.

To update the firmware, you will need a USB flash drive that meets the following requirements:

  • at least 4 GB of memory
  • USB interface generation 2.0 or higher
  • FAT 32 file system

Firmware update procedure:

1. Export the data first if you wish to save the archive (see “Archive data export” at the end of the section)

2. Download the archive (zip file) with the firmware to your PC by following this link:

https://doc.omnicomm.ru/port/images/port_update_1.3.1.zip

3. Format the USB flash drive with the FAT 32 file system

IMPORTANT! Full flash drive formatting is required.

  • Insert the USB flash drive into the USB port of the PC
  • In the File Explorer window on your PC, select the USB flash drive, right-click, and select “Format”

Formatting

  • Set the following formatting parameters:
    • “File system” – select “FAT32 (default)”
    • “Allocation unit size” – select “Standard cluster size” кластера»
    • “Formatting methods” – uncheck “Quick (clean the table of contents)”
  • Click the “Start” button and wait for the formatting to finish.

4. Extract the zip file to the prepared USB flash drive:

USB flash-носитель

5. Go to the utils / win64 directory:

Launch the “makeboot64” file. A window will open:

Press “Enter” three times.

6. Safely remove the USB flash drive from the PC.

In Windows, click the USB icon in the system tray and select “Safely Remove Hardware”.

In Linux, use the sync command.

7. Turn off Omnicomm PORT by pressing the power button:

Power button

8. Connect the USB flash drive to Omnicomm PORT using the USB cable provided:

Со стороны Omnicomm PORT Со стороны USB flash-носителя

9. Turn on Omnicomm PORT by pressing the power button. The firmware update will start automatically and takes about 10 minutes

Do not disconnect Omnicomm Port and the USB cable (USB flash drive) until the update is completed

10. When the Omnicomm Port update process is completed, you will hear five short beeps, the device will automatically turn off, and the green indicator of the power button will turn off

Remove the USB flash drive to avoid running the update again.

11. Turn on Omnicomm PORT by pressing the power button. Ensure that the firmware version number is 1.3.1

Firmware version number:

Configuration window

12. Set up Omnicomm PORT and import archive data if necessary

Archive data export

In the browser, enter the address of the local communication server. Default value – 192.168.5.100:8090. A window will open:

Authorization window

“Login” – enter “user”

“Pass” – enter “pass”

Click “Log in”. A window will open:

Main window

Click the “Information and settings” button and go to the “Data export” section:

Data export

Indicate the time period for which you want to save the data. Press the button “Start export”.